Refurbished Micro Medical 3L Spirometer Calibration Syringe

Sold Out
Refurbished Micro Medical 3L Spirometer Calibration Syringe
Regular price £449.00 EXCL. VAT
£538.80 INCL. VAT
  • A volume accuracy check should be performed daily
  • A 3 litre calibration syringe should be used
  • This calibration syringe should have an accuracy of ±0.5% (15 mL for a 3 litre syringe)
  • The syringe should be discharged through the device at least three times to give a range of flows varying between 0.5 and 12 litres/second (with 3 litre injection times of approximately 6s for the lower flow limit and less than 0.5s for the upper flow limit)
  • The volume at each flow should meet the accuracy requirement of ±3.5%

About the Refurbished Micro Medical 3L Spirometer Calibration Syringe

The Micro Medical 3 Litre Spirometer Calibration Syringe is designed to simplify the process of spirometer calibration and ensure that devices are functioning correctly.  Used correctly, the syringe holds exactly 3 litres of air, which can be passed through a spirometer in line with its maintenance schedule and guidelines.  Each Micro Medical accuracy checking syringe is supplied with a unique certificate confirming ATS/ERS 2005 performance compliance. Usage recommendations The following are the recommended guidelines when performing a volume verification for...

The Micro Medical 3 Litre Spirometer Calibration Syringe is designed to simplify the process of spirometer calibration and ensure that devices are functioning correctly. 

Used correctly, the syringe holds exactly 3 litres of air, which can be passed through a spirometer in line with its maintenance schedule and guidelines.  Each Micro Medical accuracy checking syringe is supplied with a unique certificate confirming ATS/ERS 2005 performance compliance.

Usage recommendations

The following are the recommended guidelines when performing a volume verification for flow measuring devices such as Micro Medical Spirometers ATS/ERS 2005(I):

  • A volume accuracy check should be performed daily
  • A 3 litre calibration syringe should be used
  • This calibration syringe should have an accuracy of ±0.5% (15 mL for a 3 litre syringe)
  • The syringe should be discharged through the device at least three times to give a range of flows varying between 0.5 and 12 litres/second (with 3 litre injection times of approximately 6s for the lower flow limit and less than 0.5s for the upper flow limit)
  • The volume at each flow should meet the accuracy requirement of ±3.5%

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • iDEAL Wero
  • Maestro
  • Mastercard
  • PayPal
  • Satispay
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Enquire About This Product

Share a few details below, and a member of our team will get back to you with the latest availability and estimated lead time.

Your Course Details

Enter your contact details, number of attendees, preferred date and location. Your course will be added to the cart when you save these details.